SPECIFICATIONS — T. CLEAR PROTECTED MEMBRANE ROOF SYSTEMS



Click Here for a Printer Friendly Version



 
 

LIGHTGUARD® & COOLGUARD® PHYSICAL PROPERTIES

 

CLICK ON ITEMS TO DOWNLOAD PDF FILES

T. Clear PMR McGraw Hill Construction Network for Products brochure

LIGHTGUARD Material Safety Data Sheets

HEAVYGUARD Material Safety Data Sheets

COOLGUARD Sales Sheet

COOLGUARD Material Safety Data Sheets

TECH DATA

TECH DATA 4.3.2
Lightweight Protected Membrane Roofing Utilizing LIGHTGUARD


TECH DATA 4.4
Wind Design & Securement for T. Clear PMR using LG, HG, Gravel & Paver Ballasts


TECHNICAL Data Sheet No.20

LIGHTGUARD® and HEAVYGUARD®

LIGHTGUARD® & HEAVYGUARD® Insulation for Built-Up Bituminous Roofing

LIGHTGUARD® & HEAVYGUARD® Insulation for Modified Bituminous Membrane Roofing

LIGHTGUARD® & HEAVYGUARD® Protected Single-Ply Membrane Roofing System

To read these PDF files Acrobat Reader® is necessary. For a free copy click below.

Attributes

 

Value

 

Test

Extruded Polystyrene

Type VI

ASTM C 578-92

Tongue & Groove Long Edges

 

 

Latex Modified Concrete Face

3/8" (10mm)

 

Finished Overall Dimensions

24" wide (610mm)

 

 

48" long (1219mm)

 

 

2.375" thick (61 mm) for 2" foam

 

 

3.375" thick (86 mm) for 3" foam

 

 

 

 

Weight

4.5 lbs./sq.ft. (22kg/m2)

 

R-value

5 per inch of foam (0.03m2 K/W per mm)

ASTM C 518-91

Thermal Conductivity

0.2

 

Compressive Strength (Foam Insulation)

40 lbs./sq.in. (275.6 kPa)

ASTM D 1621-79

Steel Ball Impact

Slight indentations <0.05 (1.3mm)

FM 4470

Point Loading (1"x1")

450 lbs./sq.in. (3101kPa)

 

Freeze/Thaw

750 cycles

ASTM C 666 "B"-92

Water Absorption

<0.1

ASTM D 2842-90

Permeability

0.8

ASTM E 96-95

 

HEAVYGUARD® PHYSICAL PROPERTIES

Attributes

 

Value

 

Test

Extruded Polystyrene

Type VI

ASTM C 578-92

Tongue & Groove Long Edges

 

 

Latex Modified Concrete Face

15/16" (25mm)

 

Finished Overall Dimensions

24" wide (610mm)

 

 

48" long (1219mm)

 

 

2.938" thick (75.5 mm) for 2" foam

 

 

3.938" thick (100 mm) for 3" foam

 

 

 

 

Weight

11 lbs./sq.ft. (54kg/m2)

 

R-value

5 per inch of foam (0.03m2 K/W per mm)

ASTM C 518-91

Thermal Conductivity

0.2

 

Compressive Strength (Foam Insulation)

40 lbs./sq.in. (275.6 kPa)

ASTM D 1621-79;

2" Steel Ball Drop

700 ft.lbs. (952J)

FM 4470

Point Loading (1"x1")

1300 lbs./sq.in. (8958kPa)

 

Freeze/Thaw

750 cycles

ASTM C 666 "B"-92

Water Absorption

<0.1

ASTM D 2842-90

Permeability

0.8

ASTM E 96-95

 

List Of Approved Deck/Membrane Assemblies Acceptable To T.Clear

 

Metal
Deck

Monolithic
Concrete

Panel
Concrete

Wood
Deck

Wood
Fiber

Insulated
Concrete

Existing
System

FULLY ADHERED

Fiberglass
B.U.R.

Approved
S-BA-3-AD

Approved
C-BA-3-AD

Approved
P-BA-3-AD

No

Approved
F-BA-3-AD

No

No

Modified
Bitumen

Approved
S-MB-2-AD

Approved
C-MB-1-AD

Approved
P-MB-2-AD

No

Approved
F-MB-2-AD

No

No

Single-
Ply

Approved
S-TS(P)-1-AD

Approved
C-TS(P)-1-AD

Approved
P-TS(P)-1-AD

No

Approved
F-TS(P)-1-AD

No

No

MECHANICALLY ATTACHED (T. Clear air barrier criteria must be incorporated)

Fiberglass
B.U.R

Approved
S-BA-3-MA

No

No

Approved
W-BA-3-MA

Approved
F-BA-3-MA

Approved
I-BA-3-MA

Approved
E-BA-3-MA

Modified
Bitumen

Approved
S-MB-3-MA

No

No

Approved
W-MB-2-MA

Approved
F-MB-2-MA

Approved
I-MB-2-MA

Approved
E-MB-2-MA

Single-
Ply

Approved
S-TS(P)-1-MA

No

No

Approved
W-TS(P)-1-MA

Approved
F-TS(P)-1-MA

Approved
I-TS(P)-1-MA

Approved
E-TS(P)-1-MA

LOOSE LAID (T. Clear air barrier criteria must be incorporated)

Single-
Ply

Approved
S-TS(P)-1-LL

Approved
C-MB-TS(P)-1-LL

Approved
P-TS(P)-1-LL

Approved
W-TS(P)-1-LL

Approved
F-TS(P)-1-LL

Approved
I-TS(P)-1-LL

Approved
E-TS(P)-1-LL


ROOF MEMBRANE ASSEMBLY CODES

Deck Type

 

Membrane Type

 

No. Plys

 

Means of Attachment

S - Steel

BA - Asphalt BUR

1

MA - Mechanically-Attached

I - Insulated Concrete

BC - Coal Tar Pitch BUR Asphalt BUR

2

AD - Adhered

G - Gypsum

MB - Modified Bitumen

3

LL - Loose-Laid

W - Wood & Plywood

TS - Thermoset Membrane

4

 

F - Wood Fiber

TP - Thermoplastic Membrane

 

 

P - Pre-Cast Concrete

HA - Hot-Applied Liquid

 

 

C - Concrete Poured

 

 

 

E - Existing

 

 

 

Example: S = Steel, BA = Asphalt BUR, 3 = 3 Ply, AD = Adhered S-BA-3-AD


| Trademark and Copyright | Privacy | ©2005 T. Clear Corp. & Fin Pan, Inc. All rights reserved.